Two hinged doors in series.
Double swing door ada clearance.
The measurement starts from the point where a person has 9 inch vertical clearance for their feet and 27 inch vertical clearance for their knees.
Doors in series shall swing either in the same direction or away from the space between the doors.
Clear floor space at controls must be located outside the door swing to prevent users from getting hit by the door.
Door clearances sources 26 ada sources 309 operable parts 404 2 manual doors doorways and manual gates 404 2 2 double leaf doors and gates 404 2 4 maneuvering clearances 404 3 5 automatic and power.
The ada home page provides access to americans with disabilities act ada regulations for businesses and state and local governments technical assistance materials ada standards for accessible design links to federal agencies with ada responsibilities and information updates on new ada requirements streaming video information about department of justice ada settlement agreements.
Controls for powered doors have a level 30 x 48 clr flr space outside of the door swing and centered on the control per cbc.
The minimum space between two hinged or pivoted doors in series shall be 48 in 1220 mm plus the width of any door swinging into the space.
404 3 6 break out opening.
4 13 7 two doors in series.
Two hinged doors in series.
According to the 2010 update to adaag the basic ada guidelines for a single user restroom are.
Ada door handle requirements.
Closing speed if a door is equipped with an automatic closing device.
The clear floor space adjacent to the control shall be located beyond the arc of the door swing.
On the parallel side beyond the latch is 24 inches should the door need to swing open wide.
Ada compliant door closers shall be adjusted so that from an open position of 90 degrees the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
Clear floor space at door control must be located outside door swing.
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches 455 mm of the latch side of a doorway projects more than 8 inches 205 mm beyond the face of the.
Figure 404 2 4 2 maneuvering clearances at doorways without doors sliding doors gates and folding doors 404 2 4 3 recessed doors and gates.
Door and gate controls must be compliant as operable parts operable with one hand and without tight grasping pinching twisting of the wrist or more than 5 lbf.
Where doors and gates without standby power are a part of a means of egress the clear break out opening at swinging or sliding doors and gates shall be 32 inches 815 mm minimum when operated in emergency mode.